Industrial Blower
Magnetic Suspension Blower
Magnetic suspension blower combines high efficiency, energy savings, low environmental impact, intelligent control, and long lifespan into one advanced system. During operation, the magnetic suspension blower can easily connect with a user's central control system for integrated control, allowing for real-time monitoring and operation. It offers a contactless operation and can save more than 30% on electricity, effectively reducing energy consumption and operational losses.
Request a Quote
Applications
Magnetic suspension blowers are extensively used in municipal and industrial wastewater treatment, desulfurization oxidation in power metallurgy, pipeline transportation of powder and particulate materials, and low-pressure air delivery in the petrochemical industry. Additionally, they provide clean, oil-free air for the food and pharmaceutical industries.
Features
- Highly efficient, saves over 30% on electrical energy on average compared to traditional Roots blowers.
- Features a fully enclosed casing for low noise and no vibration, with noise levels below 80 decibels and no need for foundational support or bolt-down.
- Offers efficient air management through an intelligent, user-friendly touchscreen with five operational modes and five protective functions.
- Utilizes magnetic bearing technology for a semi-permanent design lasting over 20 years with no efficiency degradation over the life cycle.
- Its high integration level results in a compact size and lightweight, making installation easy.
Technical Data
XRCF30-XRCF150 (60-120kPa)
Model | XRCF30 | XRCF40 | XRCF50 | XRCF60 | XRCF75 | XRCF100 | XRCF125 | XRCF150 |
Power | kW | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 |
Discharge Pressure | kPa | Flow (m/min):1 atm, 20℃, humidity 65% |
60 | 20 | 27 | 34 | 42 | 52 | 69 | 82 | 105 |
80 | 17 | 23 | 28 | 34 | 43 | 56 | 71 | 84 |
100 | - | - | 22 | 26 | 35 | 48 | 57 | 73 |
120 | - | - | - | - | - | 39 | 48 | 58 |
Dimensions (mm) | W | 780 | 780 | 780 | 950 | 950 | 950 | 1250 | 1250 |
L | 1820 | 1820 | 1820 | 1860 | 1860 | 1860 | 1950 | 1950 |
H | 1390 | 1390 | 1390 | 1780 | 1780 | 1780 | 2000 | 2000 |
Weight | kg | 450 | 450 | 450 | 700 | 700 | 700 | 1250 | 1250 |
Pipe Diameter | DN150 | DN150 | DN150 | DN200 | DN200 | DN200 | DN300 | DN300 |
XRCF200-XRCF1000 (60/80/120kPa)
Model | XRCF200 | XRCF250 | XRCF300 | XRCF400 | XRCF500 | XRCF600 | XRCF800 | XRCF1000 |
Power | kW | 150 | 185 | 220 | 300 | 375 | 450 | 600 | 750 |
Discharge Pressure | kPa | Flow (m/min):1 atm, 20℃, humidity 65% |
60 | 140 | 160 | 210 | 272 | 320 | 420 | 545 | 640 |
80 | 109 | 135 | 164 | 216 | 270 | 325 | 430 | 540 |
100 | 96 | 118 | 145 | 190 | 225 | 270 | 360 | 452 |
120 | 78 | 95 | 117 | 156 | 200 | 240 | 318 | 400 |
Dimensions (mm) | W | 1350 | 1350 | 1350 | 1350 | 1450 | 1450 | 1800 | 1800 |
L | 2080 | 2080 | 2480 | 2480 | 2650 | 2650 | 3500 | 3500 |
H | 2200 | 2200 | 2570 | 2570 | 2600 | 2600 | 3000 | 3000 |
Weight | kg | 1500 | 1500 | 2300 | 2300 | 2900 | 2900 | 3500 | 3500 |
Pipe Diameter | DN300 | DN300 | DN400 | DN400 | DN500 | DN500 | DN600 | DN600 |
XRCF30-XRCF400 (40kPa)
Model | XRCF30 | XRCF40 | XRCF50 | XRCF60 | XRCF75 | XRCF100 | XRCF125 | XRCF150 | XRCF200 | XRCF250 | XRCF300 | XRCF400 |
Power | kW | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 150 | 185 | 220 | 300 |
Discharge Pressure | kPa | Flow (m/min):1 atm, 20℃, humidity 65% |
40 | 30 | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 |
Dimensions (mm) | W | 780 | 780 | 950 | 950 | 950 | 125 | 125 | 1350 | 1350 | 1450 | 1450 | 1450 |
L | 1820 | 1820 | 1860 | 1860 | 1860 | 1950 | 1950 | 2080 | 2080 | 2650 | 2650 | 2650 |
H | 1390 | 1390 | 1780 | 1780 | 1780 | 2000 | 2000 | 2200 | 2200 | 2600 | 2600 | 2600 |
Weight | kg | 470 | 470 | 700 | 700 | 1250 | 1250 | 1450 | 1500 | 1500 | 2300 | 2900 | 2900 |
Pipe Diameter | DN150 | DN150 | DN200 | DN200 | DN200 | DN300 | DN300 | DN300 | DN400 | DN400 | DN400 | DN400 |